Cellulose Insulation
-
Manufacturer
-
Weight
| Manufacturer | Igloo Cellulose |
| Weight | 11.3 kg |
| Manufacturer | Igloo Cellulose |
| Weight | 11.3 kg |
Recycled-paper cellulose made in Dorval, Quebec. It has been insulating Canadian homes for decades, it is easy to source, and its fossil carbon footprint is a fraction of most conventional insulation. Simple, proven and low carbon.
Cellulose is one of the best understood insulations on the market. It turns waste paper into insulation, stores carbon from the wood fibre it is made of, and blows into attics and wall cavities with no gaps around wiring, framing and irregular shapes. We carry it alongside hemp and wood fibre because it is often the most practical low-carbon choice for attics, retrofits and deep wall cavities.
Sorted newsprint and cardboard make up 80 to 85% of each bag. A mineral treatment, mainly boric acid, controls fire, mould and pests.
A third-party verified EPD (ASTM EPD 910) reports the full life cycle, from paper collection to landfill, with low fossil emissions.
Blown fibre wraps around wiring, boxes and framing. Dense-packed in walls it also cuts air movement and sound.
Certified to CAN/ULC-S703, CCMC listed for attics and walls, GREENGUARD Gold and low-VOC certified.
Blown loose over the ceiling to any depth, new or on top of old insulation. The quickest way to bring an attic to R-50 or R-60.
Blown at high density into closed cavities, behind netting in new walls or through small holes in existing ones. Packed tight, it does not settle.
Double-stud, Larsen truss and I-joist walls and roofs reach high R-values at low cost per R, which makes it a common choice for Passive House level projects.
Our RBQ-licensed collaborators can install it for you, including dense-pack walls, which need the right machine settings and density checks. Ask us for a quote.
Loose-fill attics are a manageable DIY job. We can help you rent an IGLOO blowing machine and plan the quantity. Dense-pack walls are best left to an installer.
Based on IGLOO's installation chart (blown over a horizontal surface, no joists, 12% standard settling). R-values are for the settled depth.
Gross area, framing not deducted, so the bag count runs slightly high. Uses the minimum dense-pack density of 48 kg/m³ (3 lb/ft³); installers often pack denser.
The value is for the cellulose in the cavity only. Studs lower the whole-wall value.
Estimates only. Volume pricing is available on larger orders: ask us for a quote.
Per m² of insulation at RSI 1 (R-5.7), over a 75-year service life, packaging included. Fossil emissions and biogenic carbon are accounted differently, so they are shown separately and not added together.
| Attic, loose-fill | Wall, dense-pack | |
|---|---|---|
| Mass per m² at RSI 1 | 1.10 kg | 1.86 kg |
| Fossil, production A1 to A3 | 0.261 | 0.436 |
| Fossil, transport and installation A4, A5 | 0.037 | 0.061 |
| Fossil, end of life C1 to C4 | 0.049 | 0.081 |
| Fossil, total | 0.347 | 0.578 |
| Biogenic carbon stored in the fibre (A1) | 1.35 | 2.26 |
| Biogenic carbon released in landfill (C4) | 0.28 | 0.46 |
Source: ASTM EPD 910, IGLOO Cellulose, valid February 2025 to February 2030. Fossil values in kg CO₂e (IPCC 2013), biogenic in kg CO₂. The EPD assumes 100% landfill at end of life, with about 20% of the stored carbon re-emitted. Boric acid is the largest contributor to production impacts.
| Product | IGLOO Cellulose®, loose-fill cellulose fibre insulation |
|---|---|
| Composition | Recovered newsprint and cardboard (80 to 85%), boric acid (10 to 15%), magnesium sulfate, additives for mould, dust and fire control |
| Thermal resistance | R-3.71 per inch (RSI 0.65 per 25 mm), ASTM C177 and C518. Thermal conductivity 0.0387 W/(m·K) |
| Density | Loose-fill: 24.9 kg/m³ (1.6 lb/ft³) Dense-pack walls: at least 48 kg/m³ (3 lb/ft³) |
| Settling | 12% standard; 12 to 20% above about 12 in (R-40) |
| Surface burning | Flame spread below 150 (CAN/ULC-S102.2), equivalent below 25 (CAN/ULC-S102, ASTM E84) |
| Critical radiant flux | At least 0.12 W/cm² (ASTM E970) |
| Smoulder resistance | Less than 15% mass loss (CAN/ULC-S130); self-extinguishes when the heat source is removed |
| Moisture sorption | Less than 20% after 168 h at 90% RH and 50 °C |
| Mould resistance | No fungal growth after 28 days at 95% RH and 28 °C (ASTM C1338) |
| Corrosiveness | No perforation of aluminum, copper, steel or galvanized steel after 28 days at 50 °C (ASTM G1) |
| Chemical separation | Less than 1.5% after 30 min agitation |
| pH | 7.8 (2% solution at 25 °C) |
| Certifications | CAN/ULC-S703-09 · CCMC 08532-L (attics) and 12835-R (walls) · GREENGUARD Gold · Low VOC certificate 120120-03 (Berkeley Analytical) · EPD ASTM 910 |
| Service temperature | Up to 90 °C (194 °F) |
| Packaging | 25 lb (11.3 kg) bag |
Values from IGLOO Cellulose's technical data sheet (May 2025) and EPD 910 (February 2025). Calculator results are estimates for planning; confirm quantities with your installer. Follow the manufacturer's instructions and confirm code requirements with your municipality.
De la cellulose de papier recyclé fabriquée à Dorval, au Québec. Elle isole les maisons canadiennes depuis des décennies, elle est facile à obtenir et son empreinte de carbone fossile est une fraction de celle de la plupart des isolants conventionnels. Simple, éprouvée et faible en carbone.
La cellulose est l'un des isolants les mieux connus sur le marché. Elle transforme le papier rebuté en isolant, stocke le carbone de la fibre de bois dont elle est faite et se souffle dans les entretoits et les cavités murales sans laisser de vides autour du filage, de l'ossature et des formes irrégulières. Nous l'offrons aux côtés du chanvre et de la fibre de bois parce qu'elle est souvent le choix faible en carbone le plus pratique pour les entretoits, les rénovations et les murs à cavité profonde.
Le papier journal et le carton triés forment 80 à 85 % de chaque sac. Un traitement minéral, surtout de l'acide borique, protège contre le feu, la moisissure et les insectes.
Une DEP vérifiée par une tierce partie (ASTM EPD 910) couvre tout le cycle de vie, de la collecte du papier à l'enfouissement, avec de faibles émissions fossiles.
La fibre soufflée enveloppe le filage, les boîtes électriques et l'ossature. Injectée à haute densité dans les murs, elle réduit aussi les mouvements d'air et le bruit.
Certifiée CAN/ULC-S703, évaluée par le CCMC pour les entretoits et les murs, certifiée GREENGUARD Gold et à faibles émissions de COV.
Soufflée en vrac sur le plafond, à la profondeur voulue, en neuf ou par-dessus l'ancien isolant. La façon la plus rapide d'amener un entretoit à R-50 ou R-60.
Injectée à haute densité dans les cavités fermées, derrière un filet dans les murs neufs ou par de petits trous dans les murs existants. Bien compactée, elle ne se tasse pas.
Les murs et toits à double ossature, à fermes Larsen ou à poutrelles en I atteignent des valeurs R élevées à faible coût par R, un choix courant pour les projets de niveau Maison passive.
Nos collaborateurs titulaires d'une licence RBQ peuvent faire l'installation, y compris les murs à haute densité, qui demandent les bons réglages de machine et un contrôle de la densité. Demandez-nous une soumission.
Souffler un entretoit en vrac est un projet réaliste pour les autoconstructeurs. Nous pouvons vous aider à louer une souffleuse IGLOO et à planifier la quantité. Pour les murs à haute densité, mieux vaut un installateur.
Selon le tableau de pose d'IGLOO (soufflée sur une surface horizontale, sans solives, tassement normalisé de 12 %). Les valeurs R correspondent à l'épaisseur après tassement.
Surface brute, ossature non déduite : le nombre de sacs est donc légèrement surestimé. Utilise la densité minimale de 48 kg/m³ (3 lb/pi³); les installateurs compactent souvent davantage.
Cette valeur vise seulement la cellulose dans la cavité. Les montants réduisent la valeur globale du mur.
Estimations seulement. Des prix de volume sont offerts pour les commandes importantes : demandez-nous une soumission.
Par m² d'isolant à RSI 1 (R-5,7), sur une durée de vie de 75 ans, emballage inclus. Les émissions fossiles et le carbone biogénique ne se comptabilisent pas de la même façon : ils sont donc présentés séparément, sans être additionnés.
| Entretoit, en vrac | Mur, haute densité | |
|---|---|---|
| Masse par m² à RSI 1 | 1,10 kg | 1,86 kg |
| Fossile, production A1 à A3 | 0,261 | 0,436 |
| Fossile, transport et installation A4, A5 | 0,037 | 0,061 |
| Fossile, fin de vie C1 à C4 | 0,049 | 0,081 |
| Fossile, total | 0,347 | 0,578 |
| Carbone biogénique stocké dans la fibre (A1) | 1,35 | 2,26 |
| Carbone biogénique libéré à l'enfouissement (C4) | 0,28 | 0,46 |
Source : ASTM EPD 910, Cellulose IGLOO, valide de février 2025 à février 2030. Valeurs fossiles en kg CO₂e (GIEC 2013), biogéniques en kg CO₂. La DEP suppose un enfouissement à 100 % en fin de vie, avec environ 20 % du carbone stocké réémis. L'acide borique est le principal contributeur aux impacts de production.
| Produit | Cellulose IGLOO®, isolant de fibre cellulosique à bourrage lâche |
|---|---|
| Composition | Papier journal et carton récupérés (80 à 85 %), acide borique (10 à 15 %), sulfate de magnésium, additifs pour le contrôle des moisissures, de la poussière et du feu |
| Résistance thermique | R-3,71 par pouce (RSI 0,65 par 25 mm), ASTM C177 et C518. Conductivité thermique 0,0387 W/(m·K) |
| Masse volumique | En vrac : 24,9 kg/m³ (1,6 lb/pi³) Murs à haute densité : au moins 48 kg/m³ (3 lb/pi³) |
| Tassement | 12 % normalisé; 12 à 20 % au-delà d'environ 12 po (R-40) |
| Combustion superficielle | Indice de propagation de la flamme inférieur à 150 (CAN/ULC-S102.2), équivalent inférieur à 25 (CAN/ULC-S102, ASTM E84) |
| Flux radiant critique | Au moins 0,12 W/cm² (ASTM E970) |
| Combustion sans flamme | Perte de masse inférieure à 15 % (CAN/ULC-S130); s'éteint lorsque la source de chaleur disparaît |
| Absorption d'humidité | Moins de 20 % après 168 h à 90 % HR et 50 °C |
| Résistance aux moisissures | Aucune croissance fongique après 28 jours à 95 % HR et 28 °C (ASTM C1338) |
| Corrosivité | Aucune perforation de l'aluminium, du cuivre, de l'acier ou de l'acier galvanisé après 28 jours à 50 °C (ASTM G1) |
| Séparation des produits chimiques | Moins de 1,5 % après 30 min d'agitation |
| pH | 7,8 (solution à 2 % à 25 °C) |
| Certifications | CAN/ULC-S703-09 · CCMC 08532-L (entretoits) et 12835-R (murs) · GREENGUARD Gold · Certificat faibles COV 120120-03 (Berkeley Analytical) · DEP ASTM 910 |
| Température de service | Jusqu'à 90 °C (194 °F) |
| Emballage | Sac de 25 lb (11,3 kg) |
Valeurs tirées de la fiche technique de Cellulose IGLOO (mai 2025) et de la DEP 910 (février 2025). Les résultats du calculateur sont des estimations pour la planification; confirmez les quantités avec votre installateur. Suivez les instructions du fabricant et vérifiez les exigences du code auprès de votre municipalité.
Recycled-paper cellulose made in Dorval, Quebec. It has been insulating Canadian homes for decades, it is easy to source, and its fossil carbon footprint is a fraction of most conventional insulation. Simple, proven and low carbon.
Cellulose is one of the best understood insulations on the market. It turns waste paper into insulation, stores carbon from the wood fibre it is made of, and blows into attics and wall cavities with no gaps around wiring, framing and irregular shapes. We carry it alongside hemp and wood fibre because it is often the most practical low-carbon choice for attics, retrofits and deep wall cavities.
Sorted newsprint and cardboard make up 80 to 85% of each bag. A mineral treatment, mainly boric acid, controls fire, mould and pests.
A third-party verified EPD (ASTM EPD 910) reports the full life cycle, from paper collection to landfill, with low fossil emissions.
Blown fibre wraps around wiring, boxes and framing. Dense-packed in walls it also cuts air movement and sound.
Certified to CAN/ULC-S703, CCMC listed for attics and walls, GREENGUARD Gold and low-VOC certified.
Blown loose over the ceiling to any depth, new or on top of old insulation. The quickest way to bring an attic to R-50 or R-60.
Blown at high density into closed cavities, behind netting in new walls or through small holes in existing ones. Packed tight, it does not settle.
Double-stud, Larsen truss and I-joist walls and roofs reach high R-values at low cost per R, which makes it a common choice for Passive House level projects.
Our RBQ-licensed collaborators can install it for you, including dense-pack walls, which need the right machine settings and density checks. Ask us for a quote.
Loose-fill attics are a manageable DIY job. We can help you rent an IGLOO blowing machine and plan the quantity. Dense-pack walls are best left to an installer.
Based on IGLOO's installation chart (blown over a horizontal surface, no joists, 12% standard settling). R-values are for the settled depth.
Gross area, framing not deducted, so the bag count runs slightly high. Uses the minimum dense-pack density of 48 kg/m³ (3 lb/ft³); installers often pack denser.
The value is for the cellulose in the cavity only. Studs lower the whole-wall value.
Estimates only. Volume pricing is available on larger orders: ask us for a quote.
Per m² of insulation at RSI 1 (R-5.7), over a 75-year service life, packaging included. Fossil emissions and biogenic carbon are accounted differently, so they are shown separately and not added together.
| Attic, loose-fill | Wall, dense-pack | |
|---|---|---|
| Mass per m² at RSI 1 | 1.10 kg | 1.86 kg |
| Fossil, production A1 to A3 | 0.261 | 0.436 |
| Fossil, transport and installation A4, A5 | 0.037 | 0.061 |
| Fossil, end of life C1 to C4 | 0.049 | 0.081 |
| Fossil, total | 0.347 | 0.578 |
| Biogenic carbon stored in the fibre (A1) | 1.35 | 2.26 |
| Biogenic carbon released in landfill (C4) | 0.28 | 0.46 |
Source: ASTM EPD 910, IGLOO Cellulose, valid February 2025 to February 2030. Fossil values in kg CO₂e (IPCC 2013), biogenic in kg CO₂. The EPD assumes 100% landfill at end of life, with about 20% of the stored carbon re-emitted. Boric acid is the largest contributor to production impacts.
| Product | IGLOO Cellulose®, loose-fill cellulose fibre insulation |
|---|---|
| Composition | Recovered newsprint and cardboard (80 to 85%), boric acid (10 to 15%), magnesium sulfate, additives for mould, dust and fire control |
| Thermal resistance | R-3.71 per inch (RSI 0.65 per 25 mm), ASTM C177 and C518. Thermal conductivity 0.0387 W/(m·K) |
| Density | Loose-fill: 24.9 kg/m³ (1.6 lb/ft³) Dense-pack walls: at least 48 kg/m³ (3 lb/ft³) |
| Settling | 12% standard; 12 to 20% above about 12 in (R-40) |
| Surface burning | Flame spread below 150 (CAN/ULC-S102.2), equivalent below 25 (CAN/ULC-S102, ASTM E84) |
| Critical radiant flux | At least 0.12 W/cm² (ASTM E970) |
| Smoulder resistance | Less than 15% mass loss (CAN/ULC-S130); self-extinguishes when the heat source is removed |
| Moisture sorption | Less than 20% after 168 h at 90% RH and 50 °C |
| Mould resistance | No fungal growth after 28 days at 95% RH and 28 °C (ASTM C1338) |
| Corrosiveness | No perforation of aluminum, copper, steel or galvanized steel after 28 days at 50 °C (ASTM G1) |
| Chemical separation | Less than 1.5% after 30 min agitation |
| pH | 7.8 (2% solution at 25 °C) |
| Certifications | CAN/ULC-S703-09 · CCMC 08532-L (attics) and 12835-R (walls) · GREENGUARD Gold · Low VOC certificate 120120-03 (Berkeley Analytical) · EPD ASTM 910 |
| Service temperature | Up to 90 °C (194 °F) |
| Packaging | 25 lb (11.3 kg) bag |
Values from IGLOO Cellulose's technical data sheet (May 2025) and EPD 910 (February 2025). Calculator results are estimates for planning; confirm quantities with your installer. Follow the manufacturer's instructions and confirm code requirements with your municipality.
De la cellulose de papier recyclé fabriquée à Dorval, au Québec. Elle isole les maisons canadiennes depuis des décennies, elle est facile à obtenir et son empreinte de carbone fossile est une fraction de celle de la plupart des isolants conventionnels. Simple, éprouvée et faible en carbone.
La cellulose est l'un des isolants les mieux connus sur le marché. Elle transforme le papier rebuté en isolant, stocke le carbone de la fibre de bois dont elle est faite et se souffle dans les entretoits et les cavités murales sans laisser de vides autour du filage, de l'ossature et des formes irrégulières. Nous l'offrons aux côtés du chanvre et de la fibre de bois parce qu'elle est souvent le choix faible en carbone le plus pratique pour les entretoits, les rénovations et les murs à cavité profonde.
Le papier journal et le carton triés forment 80 à 85 % de chaque sac. Un traitement minéral, surtout de l'acide borique, protège contre le feu, la moisissure et les insectes.
Une DEP vérifiée par une tierce partie (ASTM EPD 910) couvre tout le cycle de vie, de la collecte du papier à l'enfouissement, avec de faibles émissions fossiles.
La fibre soufflée enveloppe le filage, les boîtes électriques et l'ossature. Injectée à haute densité dans les murs, elle réduit aussi les mouvements d'air et le bruit.
Certifiée CAN/ULC-S703, évaluée par le CCMC pour les entretoits et les murs, certifiée GREENGUARD Gold et à faibles émissions de COV.
Soufflée en vrac sur le plafond, à la profondeur voulue, en neuf ou par-dessus l'ancien isolant. La façon la plus rapide d'amener un entretoit à R-50 ou R-60.
Injectée à haute densité dans les cavités fermées, derrière un filet dans les murs neufs ou par de petits trous dans les murs existants. Bien compactée, elle ne se tasse pas.
Les murs et toits à double ossature, à fermes Larsen ou à poutrelles en I atteignent des valeurs R élevées à faible coût par R, un choix courant pour les projets de niveau Maison passive.
Nos collaborateurs titulaires d'une licence RBQ peuvent faire l'installation, y compris les murs à haute densité, qui demandent les bons réglages de machine et un contrôle de la densité. Demandez-nous une soumission.
Souffler un entretoit en vrac est un projet réaliste pour les autoconstructeurs. Nous pouvons vous aider à louer une souffleuse IGLOO et à planifier la quantité. Pour les murs à haute densité, mieux vaut un installateur.
Selon le tableau de pose d'IGLOO (soufflée sur une surface horizontale, sans solives, tassement normalisé de 12 %). Les valeurs R correspondent à l'épaisseur après tassement.
Surface brute, ossature non déduite : le nombre de sacs est donc légèrement surestimé. Utilise la densité minimale de 48 kg/m³ (3 lb/pi³); les installateurs compactent souvent davantage.
Cette valeur vise seulement la cellulose dans la cavité. Les montants réduisent la valeur globale du mur.
Estimations seulement. Des prix de volume sont offerts pour les commandes importantes : demandez-nous une soumission.
Par m² d'isolant à RSI 1 (R-5,7), sur une durée de vie de 75 ans, emballage inclus. Les émissions fossiles et le carbone biogénique ne se comptabilisent pas de la même façon : ils sont donc présentés séparément, sans être additionnés.
| Entretoit, en vrac | Mur, haute densité | |
|---|---|---|
| Masse par m² à RSI 1 | 1,10 kg | 1,86 kg |
| Fossile, production A1 à A3 | 0,261 | 0,436 |
| Fossile, transport et installation A4, A5 | 0,037 | 0,061 |
| Fossile, fin de vie C1 à C4 | 0,049 | 0,081 |
| Fossile, total | 0,347 | 0,578 |
| Carbone biogénique stocké dans la fibre (A1) | 1,35 | 2,26 |
| Carbone biogénique libéré à l'enfouissement (C4) | 0,28 | 0,46 |
Source : ASTM EPD 910, Cellulose IGLOO, valide de février 2025 à février 2030. Valeurs fossiles en kg CO₂e (GIEC 2013), biogéniques en kg CO₂. La DEP suppose un enfouissement à 100 % en fin de vie, avec environ 20 % du carbone stocké réémis. L'acide borique est le principal contributeur aux impacts de production.
| Produit | Cellulose IGLOO®, isolant de fibre cellulosique à bourrage lâche |
|---|---|
| Composition | Papier journal et carton récupérés (80 à 85 %), acide borique (10 à 15 %), sulfate de magnésium, additifs pour le contrôle des moisissures, de la poussière et du feu |
| Résistance thermique | R-3,71 par pouce (RSI 0,65 par 25 mm), ASTM C177 et C518. Conductivité thermique 0,0387 W/(m·K) |
| Masse volumique | En vrac : 24,9 kg/m³ (1,6 lb/pi³) Murs à haute densité : au moins 48 kg/m³ (3 lb/pi³) |
| Tassement | 12 % normalisé; 12 à 20 % au-delà d'environ 12 po (R-40) |
| Combustion superficielle | Indice de propagation de la flamme inférieur à 150 (CAN/ULC-S102.2), équivalent inférieur à 25 (CAN/ULC-S102, ASTM E84) |
| Flux radiant critique | Au moins 0,12 W/cm² (ASTM E970) |
| Combustion sans flamme | Perte de masse inférieure à 15 % (CAN/ULC-S130); s'éteint lorsque la source de chaleur disparaît |
| Absorption d'humidité | Moins de 20 % après 168 h à 90 % HR et 50 °C |
| Résistance aux moisissures | Aucune croissance fongique après 28 jours à 95 % HR et 28 °C (ASTM C1338) |
| Corrosivité | Aucune perforation de l'aluminium, du cuivre, de l'acier ou de l'acier galvanisé après 28 jours à 50 °C (ASTM G1) |
| Séparation des produits chimiques | Moins de 1,5 % après 30 min d'agitation |
| pH | 7,8 (solution à 2 % à 25 °C) |
| Certifications | CAN/ULC-S703-09 · CCMC 08532-L (entretoits) et 12835-R (murs) · GREENGUARD Gold · Certificat faibles COV 120120-03 (Berkeley Analytical) · DEP ASTM 910 |
| Température de service | Jusqu'à 90 °C (194 °F) |
| Emballage | Sac de 25 lb (11,3 kg) |
Valeurs tirées de la fiche technique de Cellulose IGLOO (mai 2025) et de la DEP 910 (février 2025). Les résultats du calculateur sont des estimations pour la planification; confirmez les quantités avec votre installateur. Suivez les instructions du fabricant et vérifiez les exigences du code auprès de votre municipalité.